November 24, 2010 - Rotational computed tomography angiography (CTA), a new noninvasive imaging modality, has the ability to display angiography in 3-D formats. This allows for considerable simplification of orientation of complex fenestrated/branched stent grafts in 3-D views, as well as catheterization of target vessels. It also enables practitioners to determine whether fenestrated/branched stent grafts are successfully deployed without leaks and thus obviates the need for immediate post-operative CTA.

The plans, constructed using multidetector CTA (MCTA) thin slice images, provide guidance for the final positioning of the fenestrated/branched stent grafts in the aorta. However, especially when the aorta is tortuous, the planned position is often an approximation to the final position achieved. This can considerably increase the technical challenges associated with placement of connecting stents.

Until recently, only 2-D angiographic images have been possible to guide placement of the endograft and connecting stents. In order to overcome this limitation, multiple views from different angles such as from the frontal anterior-posterior to lateral views, have been employed. A large amount of nephrotoxic contrast medium is often used for these repeated 2-D angiographies. Recent developments in angiographic equipment have made possible the acquisition of rotational angiography that gives a 180-degree view of the vascular tree.

“Using this new rotational CTA has proved to be very helpful in determining orientation of fenestrated/branched stent grafts,” said Krassi Ivancev, M.D., professor at the University College of London. “One way to facilitate such orientation in 3-D is to catheterize one or two of the target vessels and then, by using the capabilities of a rotational CTA without contrast medium, making it possible to orient the fenestrated/branched stent grafts accurately using the catheters in the target vessels as reference points.”

“The same technique can be employed for catheterization of target vessels whereupon a limited amount of contrast medium is used selectively only through the catheters in the target vessels, thus reducing the large amount of contrast medium otherwise necessary for routine 2-D angiography/aortogram from differently angled views,” he said.

Ivancev said it is also possible to fuse images from a pre-op MCTA with the images from a rotational CTA, and then to use the fused images for catheterization of the target vessels. In the near future rotational CTA may facilitate selection of an appropriate off-the-shelf fenestrated/branched stent graft based upon 3-D evaluation of the aorta with a large dummy sheath in place to simulate the relative behavior of stent grafts and the target vessels in the presence of tortuosity.

For more information: www.veithpress.org


Related Content

Feature | Computed Tomography (CT) | By Melinda Taschetta-Millane

Computed Tomography (CT) continues to be a rapidly evolving technology with many new advancements, as displayed and ...

Time March 07, 2024
arrow
News | Computed Tomography (CT)

February 20, 2024 — Ultrahigh-spatial-resolution photon-counting detector CT improved assessment of coronary artery ...

Time February 20, 2024
arrow
News | Radiology Business

February 1, 2024 — Banyan Software, a leading acquirer and permanent home for great software businesses, announces the ...

Time February 01, 2024
arrow
News | Medical 3-D Printing

December 6, 2023 — Materialise, a global leader in 3D planning and printing services for the medical industry, has ...

Time December 06, 2023
arrow
News | Contrast Media

August 2, 2022 – A new update has been announced as the radiology world continues to address supply disruptions of ...

Time August 02, 2022
arrow
News | Mobile C-Arms

July 29, 2022 — Siemens Healthineers has announced the Food and Drug Administration (FDA) clearance of the ARTIS icono ...

Time July 29, 2022
arrow
News | SCCT

July 8, 2022 — The Society of Cardiovascular Computed Tomography (SCCT) has released a new expert consensus document on ...

Time July 08, 2022
arrow
Videos | Radiation Oncology

Douglas E. Holt, M.D., a radiation oncologist at Eastern Idaho Regional Medical Center, explains the use of 3-D virtual ...

Time February 02, 2022
arrow
Videos | Computed Tomography (CT)

Cynthia McCollough, Ph.D., director of Mayo Clinic's CT Clinical Innovation Center, explains how photon-counting ...

Time January 27, 2022
arrow
News | Mobile C-Arms

January 18, 2022 – Philips Healthcare announced physicians will now have access to advanced new 3D image guidance ...

Time January 18, 2022
arrow
Subscribe Now