July 17, 2008 – A new study reveals that, with dual-source computed tomography (DSCT), the dosage for a heart examination can be significantly lowered, in comparison to conventional computed tomography.

The study also demonstrated that stenoses can be diagnosed with similar high accuracy as with invasive X-ray angiography. At the University Hospital Zürich in Switzerland, 120 patients with suspected coronary heart disease were scanned with the world’s first CT scanner with two X-ray tubes, a SOMATOM Definition from Siemens Healthcare. The Siemens application, Adaptive Cardio Sequence with the step-and-shoot mode, was also used for the first time with a dual-source CT. The results of the study were published in the June issue of Heart, the official journal of the British Cardiovascular Society.

Researchers at the university hospital set out to see whether the dose used during CT angiography can be reduced. The research team used Adaptive Cardio Sequence, which was recently developed by Siemens for all SOMATOM Definition Scanners. The application is based on the step-and-shoot method, in which the next respective diastole is calculated and only this phase of the cardiac cycle is used to obtain image data. The combination of Adaptive Cardio Sequence and the DSCT’s maximum time resolution of 83 msec reportedly facilitates this technique and permits significant reduction in dosage.

“The results show that CT coronary angiography with a dual-source CT in step-and-shoot mode produces images of excellent diagnostic quality in patients with stable heart rates up to 70 bpm. The dosage reduction achieved in comparison to previous CT angiography is also remarkable. In our study, we required an effective dose of 2.5 mSv on average with a deviation of plus/minus 0.8 mSv. In the literature, a normal average effective dose for heart scans of between 9 mSv and 21 mSv is reported,” said Hatem Alkadhi, M.D., specialist in radiology at the Institute for Diagnostic Radiology, University Hospital Zürich.

The Adaptive Cardio Sequence supplements the step-and-shoot method with algorithms that monitor the heart frequency of patients and, if necessary, respond to arrhythmia, such as extrasystoles, additional heart beats. In this case, the recording phase is automatically postponed in order to avoid image errors due to the sudden movement. In addition, the recording window can be widened a little more if required so that, with the Adaptive Cardio Sequence, the robustness of the CT scan can be increased significantly overall.

H. Scheffel, MD, H. Alkadhi, MD, S. Leschka, MD, A. Plass, L. Desbiolles, I. Gruber..et al: Low-Dose CT Coronary Angiography in the Step-and-Shoot Mode: Diagnostic Performance, in Heart online, June 2, 2008.

For more information: http://www.siemens.com/healthcare


Related Content

Feature | Computed Tomography (CT) | By Melinda Taschetta-Millane

Computed Tomography (CT) continues to be a rapidly evolving technology with many new advancements, as displayed and ...

Time March 07, 2024
arrow
News | Computed Tomography (CT)

February 20, 2024 — Ultrahigh-spatial-resolution photon-counting detector CT improved assessment of coronary artery ...

Time February 20, 2024
arrow
News | Contrast Media

August 2, 2022 – A new update has been announced as the radiology world continues to address supply disruptions of ...

Time August 02, 2022
arrow
News | Mobile C-Arms

July 29, 2022 — Siemens Healthineers has announced the Food and Drug Administration (FDA) clearance of the ARTIS icono ...

Time July 29, 2022
arrow
News | SCCT

July 8, 2022 — The Society of Cardiovascular Computed Tomography (SCCT) has released a new expert consensus document on ...

Time July 08, 2022
arrow
News | PET-CT

January 12, 2022 — By combining information from two advanced imaging techniques with clinical data, physicians can ...

Time January 12, 2022
arrow
Feature | Computed Tomography (CT) | By Dave Fornell, ITN Editor

The U.S. Food and Drug Administration (FDA) cleared the world's first photon-counting computed tomography (CT) scanner ...

Time November 04, 2021
arrow
News | Computed Tomography (CT)

October 14, 2021 — Cardiac computed tomography angiography (CTA) derived left atrium emptying fraction (LAEF) improves ...

Time October 14, 2021
arrow
News | Artificial Intelligence

September 27, 2021 — Zebra Medical Vision, the deep-learning medical imaging analytics company, announces its eighth U.S ...

Time September 27, 2021
arrow
News | Cardiac Imaging

September 22, 2021 — Test selection should be a shared decision between patient and physician rather than directed by ...

Time September 23, 2021
arrow
Subscribe Now