Image courtesy of Siemens Healthineers

Image courtesy of Siemens Healthineers 


September 6, 2022 —  New CT technology paired with artificial intelligence (AI)-based noise reduction offers superior detection of bone disease associated with multiple myeloma at lower radiation doses than conventional CT, according to a new study published in Radiology, a journal of the Radiological Society of North America (RSNA). 

The new technology, known as photon-counting detector CT, debuted in the clinic in 2021 after decades of development. By directly converting individual x-ray photons into an electric signal, photon-counting detector CT can decrease the detector pixel size and improve the image’s spatial resolution. 

“Additionally, photon-counting CT has demonstrated much better dose efficiency than standard CT, which allows for acquisition of ultra-high-resolution images of large areas of the body,” said study lead author Francis Baffour, M.D., diagnostic radiologist at the Mayo Clinic in Rochester, Minnesota. 

This potential for improved image quality in whole-body low-dose scans inspired Dr. Baffour and colleagues to study the technology in people with multiple myeloma, a disease that forms in a type of white blood cell found in the bone marrow called a plasma cell. Bone disease characterized by areas of bone destruction known as lytic lesions is found in approximately 80% of multiple myeloma patients. 

The International Myeloma Working Group recommends low-dose, whole-body CT to evaluate associated bone disease. Much less is known about photon-counting detector CT is this setting. 

Dr. Baffour and colleagues compared photon-counting detector CT with conventional low-dose, whole-body CT in 27 multiple myeloma patients, median age 68 years. The patients underwent whole-body scans with both types of CT and two radiologists compared the images. 

“We felt this was a prime example to showcase the ultra-high-resolution of photon-counting CT at low scanning doses,” Dr. Baffour said. 

The researchers also applied a deep learning AI technique developed at Mayo Clinic’s CT Clinical Innovation Center to reduce the noise in the very sharp photon-counting images. CT noise refers to an unwanted change in pixel values in the image, often loosely defined as the grainy appearance on cross-sectional imaging. The photon-counting detector CT with deep learning noise reduction demonstrated improvement in visualization and detected more lesions relative to conventional CT. 

“We were excited to see that not only were we able to detect these features of multiple myeloma disease activity more clearly on the photon-counting scanner,” Dr. Baffour said, “with deep learning denoising techniques that allowed us to generate thinner image slices, we were able to detect more lesions than on the standard CT.” 

The researchers hope to conduct follow-up studies on patients with multiple myeloma precursor states to see if photon-counting detector CT finds bone lesions that would upstage these patients to active multiple myeloma. 

“Our excitement as scientists and radiologists in these results stems from our realization that this scanner could make a difference in the staging of disease, potentially impact therapy choice, and ultimately, patient outcomes.” 

They also want to look at photon-counting detector CT in other instances in which low-dose protocols are beneficial, for instance, in pediatric or pregnant patients or screening applications.   

“Already there are ongoing studies to determine how low we can go with scanning doses while still obtaining diagnostic CT images,” Dr. Baffour said. “So, there is much on the horizon and so much potential for photon-counting detector CT in clinical care.” 

Dr. Baffour credited his colleagues, Cynthia McCollough, Ph.D., and Joel Fletcher, M.D., directors of Mayo Clinic’s CT Clinical Innovation Center, for their work in developing clinical applications of photon-counting detector CT. 

For more information: www.rsna.org 

Related Photon-counting CT Content: 

Mayo Clinic Begins Use of Third-Generation Photon-counting CT Clinical Research Detector 

VIDEO: New Advances in CT Imaging Technology — Interview with Cynthia McCollough, Ph.D. 

VIDEO: Photon Counting Detectors Will be the Next Major Advance in Computed Tomography — Interview with Todd Villines, M.D. 

Key Trends in Cardiac CT at SCCT 2020 

GE Healthcare Pioneers Photon Counting CT with Prismatic Sensors Acquisition 

Top Trend Takeaways in Radiology From RSNA 2020 

NeuroLogica Joins Forces with Massachusetts General Hospital to Pilot Photon Counting CT at the Patient’s Point-Of-Care Using OmniTom Elite CT 

VIDEO: Advances in Cardiac CT Imaging — Interview with David Bluemke, M.D. 


Related Content

News | Cardiac Imaging

May 17, 2024 — The Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual Meeting found that the ...

Time May 17, 2024
arrow
Sponsored Content | Case Study | Enterprise Imaging

Having the most efficient clinical workflows with enhanced diagnostic capabilities is a major goal for clinicians and ...

Time May 16, 2024
arrow
News | Artificial Intelligence

May 15, 2024 — Heart disease is the leading cause of mortality in the U.S., accounting for one out of every five deaths ...

Time May 15, 2024
arrow
News | Pediatric Imaging

May 15, 2024 — Transfer learning (TL) models trained on heterogeneous public datasets and fine-tuned using institutional ...

Time May 15, 2024
arrow
News | Radiology Business

May 14, 2024 — University Hospitals (UH) and Siemens Healthineers announce a 10-year strategic alliance that builds on ...

Time May 14, 2024
arrow
News | Prostate Cancer

May 13, 2024 — Avenda Health, an AI healthcare company creating the future of personalized prostate cancer care, unveils ...

Time May 13, 2024
arrow
News | Radiology Business

May 6, 2024 — ScreenPoint Medical’s Board of Directors has announced the appointment of Peter Kroese as the new Chief ...

Time May 06, 2024
arrow
News | Treatment Planning

May 6, 2024 — Elekta announced the acquisition of Philips Healthcare’s Pinnacle Treatment Planning System (TPS) patent ...

Time May 06, 2024
arrow
Feature | Digital Radiography (DR) | By Melinda Taschetta-Millane

Digital radiography (DR) continues to advance at a rapid pace with today’s technological innovations and evolving ...

Time May 06, 2024
arrow
News | Radiology Business

May 2, 2024 — GE HealthCare has announced a new radiation therapy computed tomography (CT) solution with innovative ...

Time May 02, 2024
arrow
Subscribe Now