News | February 17, 2015

Test provides quick, inexpensive alternative for assessing common complication

ultrasound systems, postoperative urinary retention, study

February 17, 2015 — In patients who don't resume normal urination after surgery, a simple ultrasound test can accurately diagnose the common problem of postoperative urinary retention (POUR), reports a study in Anesthesia & Analgesia.

Using ultrasound to measure bladder diameter provides a quick and inexpensive test for POUR, according to the new research by Aurélien Daurat, M.D., and colleagues of Lapeyronie University Hospital, Montpelier, France. The researchers believe their simplified approach may obviate the need for costly automated devices for measuring bladder volume.

Daurat and coauthors evaluated their simplified approach to ultrasound bladder measurement in 100 patients who were considered at risk of POUR because they were unable to void (urinate) after orthopedic surgery. Postoperative urinary retention is a common side effect after surgery and general anesthesia. If the bladder isn't emptied, POUR can prolong the patient's hospital stay and lead to potentially serious complications.

In the recovery room, all patients underwent a single ultrasound measurement of bladder diameter in the transverse dimension. These measures were obtained by nurses using a pocket-sized portable ultrasound device.

All 100 patients then underwent measurement of bladder volume using a special automated device. About half of the patients underwent placement of a catheter to drain the bladder, which allowed measurement of the actual volume of urine. The results were compared to evaluate the ultrasound's ability test to diagnose POUR—defined as an automated measurement of 600 milliliters and/or the need for catheter placement.

The average bladder diameter was about 11 cm in patients with POUR, compared with 8 to 9 cm in those without POUR. The ultrasound-measured diameter was strongly correlated with the automated bladder volume measurement or the actual urine volume.

Ultrasound bladder measurement proved to be an accurate diagnostic test for POUR. If the bladder diameter was 9.7 cm or less, the patient could be safely discharged. If the diameter was larger than 10.7 cm, POUR might be present and catheter placement should be considered. The ultrasound test would be considered inconclusive only for patients in the "grey zone" between 9.7 and 10.7 cm.

The researchers note that the test can be efficiently performed by nurses using a widely available portable ultrasound device—an important advantage over approaches using more complex measurements or specialized equipment.

For more information: www.journals.lww.com/anesthesia-analgesia


Related Content

News | Radiology Business

July 19, 2024 — GE HealthCare announced it has entered into an agreement to acquire Intelligent Ultrasound Group PLC’s ...

Time July 19, 2024
arrow
Feature | Women's Health | By Jordan Bazinsky

Investing in women’s health should not merely be a metric on the equity dashboard — it should drive policy and tactical ...

Time July 08, 2024
arrow
News | Ultrasound Women's Health

June 18, 2024 — The International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) has announced details of ...

Time June 18, 2024
arrow
News | Radiology Business

May 29, 2024 — Strategic Radiology added a third California member to the nation’s leading coalition of independent ...

Time May 29, 2024
arrow
News | Point-of-Care Ultrasound (POCUS)

May 20, 2024 — Exo (pronounced “echo”), a medical imaging software and devices company, announced the release of Exo ...

Time May 20, 2024
arrow
News | Radiology Imaging

May 13, 2024 — National Basketball Association (NBA), the National Basketball Players Association (NBPA), and the Next ...

Time May 13, 2024
arrow
News | Contrast Media

April 24, 2024 — The International Contrast Ultrasound Society (ICUS) and Northwest Imaging Forums (NWIF) announced an ...

Time April 24, 2024
arrow
News | Magnetic Resonance Imaging (MRI)

April 8, 2024 — Magnetic resonance-guided focused ultrasound (MRgFUS) is a non-invasive technique for neuroregulation ...

Time April 08, 2024
arrow
News | Radiology Business

April 4, 2024 — FUJIFILM Healthcare Americas Corporation, a leading provider of diagnostic and enterprise imaging ...

Time April 04, 2024
arrow
News | Radiation Oncology

April 2, 2024 — In a 10-center study, microwave ablation offered progression free survival rates and fewer complications ...

Time April 02, 2024
arrow
Subscribe Now