Feature | September 03, 2014 | Dave Fornell

Trends in the cath lab include a major push to lower dose, image enhancement

Allura Clarity

Angiographic imaging system vendors have developed several new technologies to address emerging cath lab trends, including the need to reduce radiation dose, improve image quality and enable advanced procedural image guidance. All three of these points have become increasingly important as more complex procedures are attempted in interventional cardiology cath labs and hybrid ORs. These procedures include transcatheter aortic valve replacement (TAVR), mitral clip valve repairs, left atrial appendage (LAA) occlusions, atrial and ventricular septal defect closures, and new interventions for both electrophysiology (EP) and heart failure.

All of the major vendors in the United States recently introduced new systems and technologies to reduce dose and enhance visualization in the cath lab. The vendors have tailored their systems into various models for specific specialties and at various price points depending on the degree of functionality. Most vendors also offer software to enhance visualization of stents and other devices.

Advanced Imaging, Guidance, Planning

Newer imaging systems enable advanced 3-D imaging with rotational angiography, which uses a quick spin around the patient to create a computed tomography (CT)-like, 3-D image of the anatomy. This can all be done tableside in the cath lab. Some systems allow these images, or CT or MRI (magnetic resonance imaging) 3-D images, to be overlaid or fused with the live 2-D fluoroscopic images. This fusion technology is used with TAVR planning and navigation software to better guide precise device placement. Software also allows 3-D images to be integrated with EP electromapping systems to guide catheter ablation procedures without the need for live fluoroscopy, helping to reduce dose.

Radiation Reduction

Ionizing radiation from medical imaging has become a growing concern, but new technologies can help reduce dose. In the cath lab, as transcatheter procedures become more complex and require longer imaging times, radiation exposure to both patients and operators is increasing.

Newer, large format displays now available for cath labs enable a larger field of view and better visualization of the anatomy, instead of operators leaning over the table to try to see anatomic details on smaller screens, said John Messenger, M.D., FACC, director, cath labs, University of Colorado, who spoke on new angiography technologies at the 2014 American College of Cardiology (ACC) meeting. He said this helps better visualize procedures and lower dose by not needing to image the anatomy several times. 

Messenger said all the major vendors recently released new angiography systems with dose-lowering technologies. These advances include new X-ray tubes and more sensitive detectors and software to help improve image quality at lower doses, in addition to noise reduction. He pointed to the Philips Allura Clarity as an example of the next-generation angiography system that can help lower standard procedural dose by 50 to 75 percent. He said the operator can easily adjust the frame rates to help reduce dose, and the system incorporates Philips’ ClarityIQ software to achieve excellent visibility at low X-ray dose levels for patients of all sizes. The software helps correct for motion, reduces noise, auto enhances the image and corrects pixel shift on cine images. The ClarityIQ technology is also available as an upgrade for the majority of Philips’ installed base of monoplane and biplane interventional X-ray systems.

The University of Colorado uses an Allura Clarity system, and when comparing it to the hospital’s older Xper systems, they found an average reduction of 750 mGy with a more than 50 percent dose reduction “These are very striking reductions in dose,” Messenger said. 

He said another recent innovation to help lower dose is Toshiba’s Spot Fluoroscopy software for its Infinix-i systems. It allows clinicians to observe a target region of anatomy using Spot Fluoro’s live fluoroscopy, while viewing the last image hold (LIH) in the surrounding area that has been collimated out of the field of view to cut dose. 

Newly Released Systems

Siemens introduced several new systems in its Artis series, including the Artis Q, Artis Q.zen and the Artis one. These incorporate both new X-ray tube and detector technology to not only lower dose, but also cut energy consumption by up to 20 percent from previous generation Artis systems. Siemens’ new X-ray tube uses flat emitter technology, which enables smaller, square focal spots that the vendor said leads to as much as 70 percent improved visibility of small vessels and improved image quality. The Artis Q.zen combines this X-ray tube with a new crystalline detector that enables patient doses as low as half the standard angiography levels.

The floor-mounted Artis one gained FDA clearance in May. It features positioning flexibility similar to ceiling-mounted systems and occupies an area of 269 square feet, compared to 484 square feet required by ceiling-mounted systems. It has several axes that can move independently, enabling easy positioning where needed. It accommodates full head-to-toe coverage of patients up to 6 feet, 10 inches without the need for patient repositioning. The on-screen, menu-guided user interface is navigated with a heads-up display. 

The Artis Q, Artis Q.zen and Artis one include the Clearstent Live application, which freezes motion in the region of a stent, allowing the physician to mask out movement of the beating heart and place the stent in precisely. The Artis one also offers new tools for cardiac imaging, including HeartSweep, which uses dual-axis rotational angiography to image the entire heart in a single, smooth C-arm movement instead of multiple acquisitions from different projections. This single-sweep movement has the potential to speed up procedures and save contrast agents. 

Shimadzu gained FDA clearance in March 2014 for its new Trinias series. It uses high-speed Score Pro image processing technology, and a smart ergonomic design aids intuitive functionality. The Score process enhances fluoroscopic images while maintaining as low as achievable dose considerations.

Designed as an angiographic interventional system, Trinias offers a new 12-inch Crossover flat panel detector for multi-procedure versatility that accommodates any type of angiography procedure. Combined with Score Pro image processing, the systems provide excellent visibility and numerous image guidance functions, as well as sophisticated 3-D application techniques. When used as a cardiac or neuro interventional system, Trinias is equipped with a new 8-inch flat panel detector. The system also has Score StentView, which improves visibility of existing stents in vessels.

GE Healthcare introduced its revolutionary Discovery IGS series in 2013. The laser-guided system captures the advantages of floor- and ceiling-mounted fixed systems and the mobility advantage of mobile C-arms without any of their inherent limitations. The imaging device is on a mobile, wheeled gantry that can be moved anywhere in the room like a mobile C-arm, but offers precision, high-quality imaging and features of a fixed system. At the touch of a button, clinicians can move the system to the table for imaging various anatomies and then move it aside and park it, allowing room to optimally position physicians, nurses, technologists, anesthesiologists and other personnel for surgery, with unobstructed access to the patient. The gantry comes with a new wide-bore design, which allows for steep angles and ease in 3-D acquisition, especially for large patients. It uses the same digital flat-panel detector technology as GE’s fixed-based Innova angiography imaging systems. 

Detector Size

When looking at systems for labs utilized by multiple users (interventional cardiology, vascular surgeons, interventional radiology, etc.) the size of the X-ray detector should be kept in mind, as different users have different requirements. Detector size is expressed in one of two ways: height and width, or as a diagonal measure from corner to corner. So a 20 x 20 cm detector can also be described as a 10-inch diagonal detector. 

Dedicated cardiac and neuro cath labs generally use smaller detectors in the range of 8-10 inch diagonal to allow steep C-arm angulations to get different views of the coronary anatomy. Larger detectors in the rage of 15-20 inch diagonal offer a larger field of view for peripheral procedures and interventional radiology.  

Comparison Chart

This article served as an introduction for a comparison chart for angiography systems on the U.S. market. To access the chart, click on the "Comparison Charts" tab at the top of the screen. Participants in the chart include:

GE Healthcare
gehealthcare.com 

Omega Medical Imaging
omegamedicalimaging.com

Philips Healthcare
usa.philips.com/healthcare

Siemens Healthcare
usa.healthcare.siemens.com

Toshiba
medical.toshiba.com

 

 


Related Content

News | Cardiac Imaging

May 17, 2024 — The Cum Laude Award-Winning Online Poster presented during the 124th ARRS Annual Meeting found that the ...

Time May 17, 2024
arrow
News | Computed Tomography (CT)

September 19, 2023 — An advanced CT test can identify individuals with stable angina at a reduced risk of three-year ...

Time September 19, 2023
arrow
News | SPECT-CT

September 12, 2022 — Royal Philips, a global leader in health technology, announced new milestones in the development of ...

Time September 12, 2022
arrow
News | Contrast Media

August 2, 2022 – A new update has been announced as the radiology world continues to address supply disruptions of ...

Time August 02, 2022
arrow
News | Mobile C-Arms

July 29, 2022 — Siemens Healthineers has announced the Food and Drug Administration (FDA) clearance of the ARTIS icono ...

Time July 29, 2022
arrow
News | Mobile C-Arms

January 18, 2022 – Philips Healthcare announced physicians will now have access to advanced new 3D image guidance ...

Time January 18, 2022
arrow
Feature | Mobile C-Arms | By Bhvita Jani

With the postponement of non-essential elective surgeries and medical procedures in 2020 to conserve medical resources ...

Time July 07, 2021
arrow
News | Angiography

December 3, 2020 — GE Healthcare is introducing a new version of its robotic driven angiography system for image guided ...

Time December 01, 2020
arrow
News | Mobile C-Arms

August 18, 2020 — Ziehm Imaging announces the acquisition of Therenva, a French-based developer of planning and imaging ...

Time August 18, 2020
arrow
News | Computed Tomography (CT)

February 10, 2020 — The U.S. Food and Drug Administration (FDA) has cleared patient-specific airway stents developed by ...

Time February 10, 2020
arrow
Subscribe Now